Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/9351
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fabris, E. | - |
dc.contributor.author | Kılıç, İsmail Doğu | - |
dc.contributor.author | Caiazzo, G. | - |
dc.contributor.author | Serdoz, R. | - |
dc.contributor.author | Foin, N. | - |
dc.contributor.author | Sinagra, G. | - |
dc.contributor.author | Di Mario, C. | - |
dc.date.accessioned | 2019-08-16T13:00:06Z | |
dc.date.available | 2019-08-16T13:00:06Z | |
dc.date.issued | 2016 | - |
dc.identifier.issn | 1558-2027 | - |
dc.identifier.uri | https://hdl.handle.net/11499/9351 | - |
dc.identifier.uri | https://doi.org/10.2459/JCM.0000000000000337 | - |
dc.description.abstract | The mechanism of restenosis in bioresorbable vascular scaffold (BVS) may be different from that of metallic stents and it is still poorly investigated. Intravascular imaging techniques are useful tools for corroborating or excluding possible mechanisms of intra-scaffold restenosis. In these novel devices intravascular imaging should be systematically used for a better comprehension of the in-scaffold restenosis mechanism. © 2017 Italian Federation of Cardiology. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Lippincott Williams and Wilkins | en_US |
dc.relation.ispartof | Journal of Cardiovascular Medicine | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | bioresorbable vascular scaffold | en_US |
dc.subject | intravascular ultrasound | en_US |
dc.subject | optical coherence tomography | en_US |
dc.subject | restenosis | en_US |
dc.subject | adult | en_US |
dc.subject | angina pectoris | en_US |
dc.subject | Article | en_US |
dc.subject | bioresorbable scaffold | en_US |
dc.subject | case report | en_US |
dc.subject | coronary artery disease | en_US |
dc.subject | dyslipidemia | en_US |
dc.subject | everolimus eluting coronary stent | en_US |
dc.subject | human | en_US |
dc.subject | in-scaffold restenosis | en_US |
dc.subject | in-stent restenosis | en_US |
dc.subject | left anterior descending coronary artery | en_US |
dc.subject | male | en_US |
dc.subject | biodegradable implant | en_US |
dc.subject | coronary angiography | en_US |
dc.subject | devices | en_US |
dc.subject | diagnostic imaging | en_US |
dc.subject | drug eluting stent | en_US |
dc.subject | interventional ultrasonography | en_US |
dc.subject | multimodal imaging | en_US |
dc.subject | predictive value | en_US |
dc.subject | procedures | en_US |
dc.subject | prosthesis design | en_US |
dc.subject | transluminal coronary angioplasty | en_US |
dc.subject | treatment outcome | en_US |
dc.subject | biocompatible coated material | en_US |
dc.subject | Absorbable Implants | en_US |
dc.subject | Adult | en_US |
dc.subject | Angioplasty, Balloon, Coronary | en_US |
dc.subject | Coated Materials, Biocompatible | en_US |
dc.subject | Coronary Angiography | en_US |
dc.subject | Coronary Artery Disease | en_US |
dc.subject | Coronary Restenosis | en_US |
dc.subject | Drug-Eluting Stents | en_US |
dc.subject | Humans | en_US |
dc.subject | Male | en_US |
dc.subject | Multimodal Imaging | en_US |
dc.subject | Predictive Value of Tests | en_US |
dc.subject | Prosthesis Design | en_US |
dc.subject | Tomography, Optical Coherence | en_US |
dc.subject | Treatment Outcome | en_US |
dc.subject | Ultrasonography, Interventional | en_US |
dc.title | Bioresorbable vascular scaffold restenosis: Intravascular imaging evaluation | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 17 | en_US |
dc.identifier.startpage | e132 | |
dc.identifier.startpage | e132 | en_US |
dc.identifier.endpage | e135 | en_US |
dc.authorid | 0000-0002-5270-3897 | - |
dc.identifier.doi | 10.2459/JCM.0000000000000337 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 26599682 | en_US |
dc.identifier.scopus | 2-s2.0-84947998354 | en_US |
dc.identifier.wos | WOS:000401257700011 | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.owner | Pamukkale University | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
crisitem.author.dept | 14.02. Internal Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
2
checked on Oct 13, 2024
Page view(s)
38
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.