Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/9581
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ertan, B. | - |
dc.contributor.author | Eren, Tanju | - |
dc.contributor.author | Ermiş, I. | - |
dc.contributor.author | Saral, H. | - |
dc.contributor.author | Atar, Necip | - |
dc.contributor.author | Yola, M.L. | - |
dc.date.accessioned | 2019-08-16T13:03:03Z | |
dc.date.available | 2019-08-16T13:03:03Z | |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0021-9797 | - |
dc.identifier.uri | https://hdl.handle.net/11499/9581 | - |
dc.identifier.uri | https://doi.org/10.1016/j.jcis.2016.02.036 | - |
dc.description.abstract | In this report, a novel molecular imprinted voltammetric sensor based on glassy carbon electrode (GCE) modified with platinum nanoparticles (PtNPs) involved in a polyoxometalate (H3PW12O40, POM) functionalized multi-walled carbon nanotubes (MWCNs) sheets was prepared for the determination of simazine (SIM). The developed surfaces were characterized by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) method. SIM imprinted GCE was prepared via electropolymerization process of 100 mM pyrrole as monomer in the presence of 0.1 M acetate buffer (pH 4.0) containing 25 mM SIM. The linearity range and the detection limit of the developed method were calculated as 1.0 × 10-10-5.0 × 10-9 M and 2.0 × 10-11 M, respectively. In addition, the voltammetric sensor was applied to wastewater samples. The stability and reproducibility of the voltammetric sensor were also reported. © 2016 Elsevier Inc. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Academic Press Inc. | en_US |
dc.relation.ispartof | Journal of Colloid and Interface Science | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Molecular imprinted sensor | en_US |
dc.subject | Multi-walled carbon nanotubes | en_US |
dc.subject | Platinum nanoparticles | en_US |
dc.subject | Polyoxometalate | en_US |
dc.subject | Simazine | en_US |
dc.subject | Carbon nanotubes | en_US |
dc.subject | Electrodes | en_US |
dc.subject | Electron microscopy | en_US |
dc.subject | Electropolymerization | en_US |
dc.subject | Glass membrane electrodes | en_US |
dc.subject | High resolution transmission electron microscopy | en_US |
dc.subject | Multiwalled carbon nanotubes (MWCN) | en_US |
dc.subject | Nanoparticles | en_US |
dc.subject | Nanotubes | en_US |
dc.subject | Oxides | en_US |
dc.subject | Platinum | en_US |
dc.subject | Scanning electron microscopy | en_US |
dc.subject | Transmission electron microscopy | en_US |
dc.subject | X ray diffraction | en_US |
dc.subject | Yarn | en_US |
dc.subject | Functionalized multi-walled carbon nanotubes | en_US |
dc.subject | Glassy carbon electrodes | en_US |
dc.subject | Platinum nano-particles | en_US |
dc.subject | Polyoxometalates | en_US |
dc.subject | Sensitive analysis | en_US |
dc.subject | Voltammetric sensor | en_US |
dc.subject | Wastewater samples | en_US |
dc.subject | X ray photoelectron spectroscopy | en_US |
dc.subject | acetic acid | en_US |
dc.subject | metal derivative | en_US |
dc.subject | multi walled nanotube | en_US |
dc.subject | platinum nanoparticle | en_US |
dc.subject | polyoxometalate | en_US |
dc.subject | pyrrole | en_US |
dc.subject | simazine | en_US |
dc.subject | unclassified drug | en_US |
dc.subject | Article | en_US |
dc.subject | chemical analysis | en_US |
dc.subject | electrode | en_US |
dc.subject | priority journal | en_US |
dc.subject | scanning electron microscopy | en_US |
dc.subject | sensor | en_US |
dc.subject | transmission electron microscopy | en_US |
dc.title | Sensitive analysis of simazine based on platinum nanoparticles on polyoxometalate/multi-walled carbon nanotubes | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 470 | en_US |
dc.identifier.startpage | 14 | |
dc.identifier.startpage | 14 | en_US |
dc.identifier.endpage | 21 | en_US |
dc.authorid | 0000-0001-8779-1412 | - |
dc.identifier.doi | 10.1016/j.jcis.2016.02.036 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 26928060 | en_US |
dc.identifier.scopus | 2-s2.0-84960510995 | en_US |
dc.identifier.wos | WOS:000373096500003 | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 10.03. Chemical Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
125
checked on Mar 29, 2025
WEB OF SCIENCETM
Citations
118
checked on Apr 1, 2025
Page view(s)
58
checked on Feb 8, 2025
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.