Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/25913
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÇağlayan, Fatma-
dc.contributor.authorSümbüllü, Muhammed Akif-
dc.contributor.authorAkgül, Hayati Murat-
dc.date.accessioned2019-09-10T11:45:23Z
dc.date.available2019-09-10T11:45:23Z
dc.date.issued2019-
dc.identifier.issn0250-832X-
dc.identifier.urihttps://hdl.handle.net/11499/25913-
dc.identifier.urihttps://doi.org/10.1259/dmfr.20180252-
dc.description.abstractObjectives: To assess the efficacy of ultrasonography (USG) in morphological and morphometric evaluation of the mental foramen (MF) compared to cone beam CT (CBCT). Methods: The measurements were established on 60 MFs of 30 patients (16 males, 14 females) with a mean age of 30.70 +/- 9,23 years. The vertical and the horizontal diameters, distance to the alveolar crest of the MF was measured by both CBCT and USG. Results obtained with CBCT and USG were statistically compared. And also the blood flow of the MF determined by Doppler USG. Results: All of the MFs could be detected by CBCT and USG. The vertical and the horizontal diameter measurements were compatible with each other by CBCT and USG. However, the distance to the alveolar crest was lower in USG than CBCT (p < 0.0001). The blood flow could be detected in all patients by Doppler USG that was weak in 8 MFs and strong in 52 MFs. Also there was no statistically significant association between the blood flow and age or gender. Furthermore, the blood flow was related with the horizontal diameter of the MF; however, it was not related with the vertical diameter and the distance to the alveolar crest. Conclusions: USG is quite effective in showing the shape, size, and the location of the MF easily and rapidly. However, it is not as accurate as CBCT in measuring the distance from the MF to alveolar crest. And also it allows to examine the flow rate of mental artery with its Doppler modes.en_US
dc.language.isoenen_US
dc.publisherBRITISH INST RADIOLOGYen_US
dc.relation.ispartofDENTOMAXILLOFACIAL RADIOLOGYen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectcone beam CT; mandible; ultrasonographyen_US
dc.subjectCOMPUTED-TOMOGRAPHYen_US
dc.titleIs ultrasonography sufficient for evaluation of mental foramen?en_US
dc.typeArticleen_US
dc.identifier.volume48en_US
dc.identifier.issue3en_US
dc.identifier.startpage1en_US
dc.identifier.endpage6en_US
dc.authorid0000-0002-0830-0054-
dc.authorid0000-0002-0666-8824-
dc.identifier.doi10.1259/dmfr.20180252-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid30426757en_US
dc.identifier.scopus2-s2.0-85062110816en_US
dc.identifier.wosWOS:000459541200007en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
crisitem.author.dept06.01. Clinical Sciences-
Appears in Collections:Diş Hekimliği Fakültesi Koleksiyonu
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
Is ultrasonography sufficient (dmfr.20180252.pdf).pdfMakale Dosyası727.49 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Sep 16, 2024

WEB OF SCIENCETM
Citations

3
checked on Sep 16, 2024

Page view(s)

46
checked on Aug 24, 2024

Download(s)

22
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.