Title: Termoelektrik soğutma dolaplı buharlaşmalı soğutucunun ısıl ve hidrolik performansının incelenmesi
Other Titles: Investigation of thermal and hydraulic performance of evaporative cooler with thermoelectric cooling cabinet
Authors: Gündüz, Anıl
Advisors: Mehmet Fevzi Köseoğlu
Keywords: Buharlaşmalı soğutma
Termoelektrik soğutma
Peltier
Termoelektrik modül
Isıl performans
Hidrolik performans
Evaporative cooling
Termoelectric cooling
Termoelectric module
Thermal performance
Hydraulic performance
Publisher: Pamukkale Üniversitesi Fen Bilimleri Enstitüsü
Abstract: Artan enerji maliyetleri ve çevreye duyarlılık düşünüldüğünde, çevre dostu ve yüksek enerji verimliliğine sahip tasarımlar ve ürünler büyük önem kazanmıştır. Bu çalışmada, buharlaşmalı soğutma ve termoelektrik soğutma prensiplerini barındıran çevre dostu ürünün 3B tasarımı, ısıl ve hidrolik performanslarının incelenmesi gerçekleştirilmiştir. Sıcak yüzeyden ısının atılma mekanizmasına ve konumuna göre 3 farklı prototip elde edilmiş ve deneysel çalışmalar ASHRAE standartlarına uygun test odasında 38°C, %20 nem kondisyon değerlerinde gerçekleştirilmiştir. Yapılan deneysel çalışmalar neticesinde termoelektrik dolabın buharlaşmalı soğutucu çalışmasına olumsuz bir etkisi olmadığı gözlemlenmiştir. Deneyler sonucunda dolap içi sıcaklıkları su soğutmalı sistemde 5°C, hava soğutmalı sistemlerde ise sıcak kanatçık çevre ortamındayken 22°C, buharlaşmalı soğutucu içerisindeyken 17°C’ye kadar düşmüştür.
Considering rising energy costs and environmental awareness, environmentally friendly and high energy efficient designs and products have gained great importance. In this study, environment-friendly 3D product design including evaporative cooling and thermoelectric cooling principles, investigation thermal and hydraulic performance has been achieved. In addition, 3 different prototypes were obtained according to the location and mechanism of heat rejection from the hot side and experimental studies were carried out in the test room in accordance with ASHRAE (American Society of Heating Refrigerating and Air Conditioning Engineers) standards at 38°C, %20 humidity. As a result of the experimental studies, it was observed that thermoelectric cabinet had no negative effect on evaporative cooler operation. As a result of the experiments, the in thermoelectric cabinet temperatures were reduced to 5°C in the water-cooled system. The thermoelectric cabinet temperature was measured at 22°C with hot heat sink in ambient conditions and 17°C with hot heat sink in evaporative cooler.
Description: Bu tez çalışması Pamukkale Üniversitesi Bilimsel Araştırma Projeleri tarafından 2018FEBE030 nolu proje ile desteklenmiştir.
URI: https://hdl.handle.net/11499/26089
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
Anıl Gündüz.pdf5.09 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

Page view(s)

122
checked on Feb 8, 2025

Download(s)

186
checked on Feb 8, 2025

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.