Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/26729
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCımbız, A-
dc.contributor.authorCavlak, U-
dc.contributor.authorSarı, M-
dc.contributor.authorHallaceli, H-
dc.contributor.authorBeydemir, F-
dc.date.accessioned2019-10-08T10:57:54Z
dc.date.available2019-10-08T10:57:54Z
dc.date.issued2006-
dc.identifier.issn1682-4474-
dc.identifier.urihttps://hdl.handle.net/11499/26729-
dc.identifier.urihttps://doi.org/10.3923/jms.2006.751.757-
dc.description.abstractThe main purposes of the study are to determine the intra-inter rater reliability of a new special designed clinical evaluation system; to measure the amount of the vertical axial rotation of the tibia resulting from passive rotation of knee and subtalar joints. To achieve this, the Measuring the Vertical Axial Rotation Tibial Shaft (MVARTS) system was designed. The system apparatus is applied to each knee and measured the vertical axial rotation of the tibia and subtalar rotations together. Fifty healthy subjects were e together. Fifty healthy subjects were examined using the suggested system. Two evaluators measured the tibial internal and external rotations, passively. The pure tibial rotation was also measured radiologically on the X-Ray in only 24 subjects The intra and inter observer variation was calculated between 2.1 and 38 degrees with high correlation (0.84-0 98). There was no significant difference between intra and inter observers' results (p 005). On the other hand, amount of the internal combined rotations was lower than the external rotation (p 001) The radiological extermal pure tibial rotations are 19.8t62 de g ( right ) , 170 1.6 İ ng ( left ) for the males whilst 28. 7+40 deg (right), 230+5.3 deg (left) for the females. The difference between the male and female subjects was also seen to be significant (p D.05). The results showed that the MVARTS system is an appropriate, noninvasive, fast to measure combined tibial and subtalar joint rotation in addition to be economically very efficient.en_US
dc.language.isoenen_US
dc.publisherANSInet Publisheren_US
dc.relation.ispartofJournal of Medical Sciencesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSubtalar Joint, tibial rotation, clinical goniometry, biomechanicsen_US
dc.titleA new clinical design measuring the vertical axial rotation through tibial shaft resulting from passive knee and subtalar joints rotation in healthy subjects: A reliability studyen_US
dc.typeArticleen_US
dc.identifier.volume6en_US
dc.identifier.issue5en_US
dc.identifier.startpage751en_US
dc.identifier.endpage757en_US
dc.identifier.doi10.3923/jms.2006.751.757-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-33845237113en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale_University-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.grantfulltextopen-
item.cerifentitytypePublications-
crisitem.author.dept16.01. Physiotherapy and Rehabilitation-
Appears in Collections:Fen-Edebiyat Fakültesi Koleksiyonu
Fizik Tedavi ve Rehabilitasyon Yüksekokulu Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
2.pdfMakale Dosyası744.7 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

5
checked on Oct 13, 2024

Page view(s)

56
checked on Aug 24, 2024

Download(s)

44
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.