Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/30381
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKutlubay, Ramazan Çağrı-
dc.contributor.authorŞekercioğlu, Tezcan-
dc.contributor.authorYörükoğlu, Ali Çağdaş-
dc.date.accessioned2020-06-08T12:12:52Z
dc.date.available2020-06-08T12:12:52Z
dc.date.issued2019-
dc.identifier.issn1869-8433-
dc.identifier.urihttps://hdl.handle.net/11499/30381-
dc.identifier.urihttps://doi.org/10.1007/978-3-030-02257-0_14-
dc.description.abstractA number of combination studies on the use of plate-screws, which has become a traditional method in fracture treatment, have been conducted to obtain a more rigid joint. These studies in the literature were reviewed and it was seen that the effect of the position of the compression screw, used with the aim of making the fracture line come closer to each other during fracture fixation, on the fatigue strength of the joint hasn’t been investigated. Within the scope of this study, a screw combination study by including Limited Contact Dynamic Compression Plate (LC-DCP) plates that possess combined hole properties was carried out. Three different combinations were created during the study. In these combinations, the unlocked screw that was located on the part where the force was applied and that was used for compression was placed in different holes and fatigue strengths of the joints were investigated under dynamic bending force. As a result of the study, it was observed that as the compression screw moved away from the fracture line, fatigue strength of the joint consisting of plate, screw and bone decreased. In addition, it was found that all the joints in the 3rd combination got damaged as a result of the fracture of the bone. © Springer Nature Switzerland AG 2019.en_US
dc.language.isoenen_US
dc.publisherSpringer Verlagen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnatomic plateen_US
dc.subjectBiomechanicsen_US
dc.subjectFatigueen_US
dc.subjectLimited contact dynamic compression plate (LCP)en_US
dc.subjectPlate screwen_US
dc.titleThe effect of the position of compression screw in plate-screws method used in fracture treatment on fatigue strength of jointen_US
dc.typeBook Parten_US
dc.identifier.volume98en_US
dc.identifier.startpage171
dc.identifier.startpage171en_US
dc.identifier.endpage182en_US
dc.authorid0000-0002-9359-8843-
dc.authorid0000-0001-8903-3578-
dc.identifier.doi10.1007/978-3-030-02257-0_14-
dc.relation.publicationcategoryKitap Bölümü - Uluslararasıen_US
dc.identifier.scopus2-s2.0-85060242864en_US
dc.identifier.scopusqualityQ3-
dc.ownerPamukkale University-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeBook Part-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
crisitem.author.dept20.03. Biomedical Engineering-
crisitem.author.dept10.07. Mechanical Engineering-
crisitem.author.dept14.01. Surgical Medicine-
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
Tıp Fakültesi Koleksiyonu
Show simple item record



CORE Recommender

Page view(s)

46
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.