Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/37050
Title: | Effects of blood contamination and hemostatic agents on bond strength in primary teeth dentin | Authors: | Erdogan, Yıldırım Karayilmaz, H. Unal, M. Gungor, O. Ciftci, Z. |
Keywords: | Blood contamination bond strength dentin hemostatic agents primary teeth Clearfil SE Bond dentin bonding agent hemostatic agent resin resin cement blood chemistry deciduous tooth dental bonding dental procedure human materials testing molar tooth shear strength Blood Composite Resins Dental Bonding Dental Stress Analysis Dentin Dentin-Bonding Agents Hemostatics Humans Materials Testing Molar Resin Cements Shear Strength Tooth, Deciduous |
Publisher: | Wolters Kluwer Medknow Publications | Abstract: | Background: Contamination is a common problem in pediatric restorative dentistry and there are a few studies that investigate blood contamination, hemostatic agents, and tooth dentin. Aim: The purpose of this study was to evaluate the effects of blood contamination and hemostatic agents on the bond strength of two different bonding systems with the dentin of primary teeth. Materials and Methods: Buccal and lingual dentin surfaces of 40 primary second molar teeth were used for this study. Specimens were divided into 4 groups according to the contamination and hemostatic agents (Blood-B, Ankaferd Blood Stopper-A, ViscoStat-V, Control-C) and then every group was further divided into two subgroups according to the bonding systems (Clearfil SE Bond-I, All Bond Universal-II, n = 10 per group). A bulk-fill composite resin was built-up on the surfaces. The specimens were tested in the micro shear mode at a crosshead speed of 1 mm/min on a universal test machine. Statistical analysis was performed with ANOVA and Tukey's tests at P < 0.05. Results: Significant differences have been detected in the micro shear bond strengths only between the Ankaferd Blood Stopper (ABS) (AI = 13.72 ± 4.47 and AII = 9.12 ± 4.4) and control groups (CI = 22.78 ± 10.86 and CII = 16.49 ± 6.55) without regards to the bonding systems. The highest scores were obtained in the control groups. Clearfil SE Bond showed better performance than All Bond Universal in all groups. Conclusion: It was determined that only the ABS contamination groups showed statistically significant decreases in the bond strengths when compared with control groups. © 2020 Wolters Kluwer Medknow Publications. All rights reserved. | URI: | https://hdl.handle.net/11499/37050 https://doi.org/10.4103/njcp.njcp_704_19 |
ISSN: | 1119-3077 |
Appears in Collections: | Diş Hekimliği Fakültesi Koleksiyonu PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
4
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
4
checked on Nov 21, 2024
Page view(s)
50
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.