Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/37108
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Demir, Ersin | - |
dc.contributor.author | Çallioglu, Hasan | - |
dc.contributor.author | Sayer, Metin | - |
dc.contributor.author | Kavla, F. | - |
dc.date.accessioned | 2021-02-02T09:24:01Z | |
dc.date.available | 2021-02-02T09:24:01Z | |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1229-9367 | - |
dc.identifier.uri | https://hdl.handle.net/11499/37108 | - |
dc.identifier.uri | https://doi.org/10.12989/scs.2020.35.6.789 | - |
dc.description.abstract | The effect of Chitosan (CS), Carbon Nanotube (CNT) and hybrid (CS-CNT) fillers on the natural frequency of drilled composite plate is investigated by experimentally in this study. The numerical validation is also made with a program based on Finite Element Method (SolidWorks). Nine types filled and one neat composite plates are used in the study. The fillers ratios are 1% CS, 2% CS, 3% CS, 0.1% CNT, 0.2% CNT, 0.3% CNT, 1% CS+0.3% CNT, 2% CS+0.3% CNT, 3% CS+0.3% CNT. The specimens cut to certain sizes by water jet from the plates 400 mm x 400 mm in dimensions. Some of them are drilled in certain dimensions with drill. The natural frequency of each specimen is measured by the vibration test set up to determine the vibration characteristic. The vibration test set up includes an accelerometer, a current source power unit, a data acquisition card and a computer. A code is written in Matlab®program for the signal processing. The study are investigated and discussed in four main points to understand the effect of the fillers on the natural frequency of the composite plate. These are the effect of fillers contents and amounts, orientation angles of fibers, holes numbers and holes sizes. As results, the natural frequency of the plate with 1% CS and 0.1% CNT hybrid filler is lower than those of the plates with other fillers ratios for 45°orientation angle. Besides, in the composite plate with 0°orientation angle, the natural frequency increases with increasing the filler ratio. Moreover, the natural frequency increases until a certain hole number and then it decreases. Furthermore, the natural frequency is not affected until a certain hole diameter but then it decreases. © 2020 Techno-Press, Ltd. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Techno-Press | en_US |
dc.relation.ispartof | Steel and Composite Structures | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Carbon nanotube | en_US |
dc.subject | Chitosan | en_US |
dc.subject | Composite plate | en_US |
dc.subject | Filler | en_US |
dc.subject | Vibration | en_US |
dc.subject | Data acquisition | en_US |
dc.subject | Fillers | en_US |
dc.subject | Infill drilling | en_US |
dc.subject | MATLAB | en_US |
dc.subject | Natural frequencies | en_US |
dc.subject | Numerical methods | en_US |
dc.subject | Plates (structural components) | en_US |
dc.subject | Signal processing | en_US |
dc.subject | Vibration analysis | en_US |
dc.subject | Composite plates | en_US |
dc.subject | Current sources | en_US |
dc.subject | Data acquisition cards | en_US |
dc.subject | Nanotube fillers | en_US |
dc.subject | Numerical validations | en_US |
dc.subject | Orientation angles | en_US |
dc.subject | Vibration behavior | en_US |
dc.subject | Vibration characteristics | en_US |
dc.subject | Carbon nanotubes | en_US |
dc.title | Effect of chitosan/carbon nanotube fillers on vibration behaviors of drilled composite plates | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 35 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 789 | |
dc.identifier.startpage | 789 | en_US |
dc.identifier.endpage | 798 | en_US |
dc.authorid | 0000-0001-8222-5358 | - |
dc.authorid | 0000-0002-4598-7975 | - |
dc.authorid | 0000-0002-5661-7507 | - |
dc.identifier.doi | 10.12989/scs.2020.35.6.789 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopus | 2-s2.0-85096197561 | en_US |
dc.identifier.wos | WOS:000546392400007 | en_US |
local.message.claim | 2023-07-10T14:43:10.049+0300|||rp00233|||submit_approve|||dc_contributor_author|||None | * |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 20.04. Mechatronics Engineering | - |
crisitem.author.dept | 20.04. Mechatronics Engineering | - |
crisitem.author.dept | 20.04. Mechatronics Engineering | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Teknoloji Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
4
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
5
checked on Nov 21, 2024
Page view(s)
62
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.