Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/38070
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOrhan, EO-
dc.contributor.authorErtuğrul, İhsan Furkan-
dc.contributor.authorTosun, Samet-
dc.date.accessioned2021-02-02T12:40:00Z-
dc.date.available2021-02-02T12:40:00Z-
dc.date.issued2021-
dc.identifier.issn1059-910X-
dc.identifier.urihttps://hdl.handle.net/11499/38070-
dc.identifier.urihttps://doi.org/10.1002/jemt.23565-
dc.description.abstractTo evaluate monotonic torsional resistance and fatigue resistance of novel SCOPE RS instruments and to compare ROTATE, Hyflex CM, OneCurve, and ProTaper Next instruments as a counterpart. The instrument groups were as follows: SCOPE RS; ROTATE; HyflexCM; OneCurve; ProTaperNext. The cyclic fatigue resistance of unused instruments was tested at both room and body temperatures (n= 10). The time to fracture, the mean number of cycles until failure, and the length of the fractured fragments were analyzed. The monotonic torsional resistance of new instruments was measured in accordingly American National Standards/American Dental Association No. 28 and International Organization for Standardization 3630-1:2008 specifications (n= 10). The maximum torque and angular deflection at break were recorded. The fractographic examination was performed by scanning electron microscope. Energy-dispersive X-ray spectroscopy was used to investigate the microstructure of NiTi instruments. One-way ANOVA with Games-Howell Post Hoc multiple comparisons tests were used (p < .05). The ROTATE had superior cyclic fatigue resistance than other groups in both temperature conditions (p < .01). However, it exhibited lower torsional resistance than SCOPE RS (p < .01). SCOPE RS had superior torsional resistance than other groups (p < .01). Micrographs revealed typical features of fatigue behaviors in all groups. Weight percentages of the Ni and Ti revealed similarity for all instruments. The novel SCOPE RS instruments presented superior monotonic torsional resistance but failed to show any improvement in the cyclic fatigue resistance compared with its counterparts, ROTATE, HyflexCM, and OneCurve.en_US
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.relation.ispartofMICROSCOPY RESEARCH AND TECHNIQUEen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectfatigue resistance; nickel-titanium; ROTATE; SCOPE RS; torsionalen_US
dc.subjectresistanceen_US
dc.titleMonotonic torsional resistance and fatigue resistance of novel SCOPE RS instrumentsen_US
dc.typeArticleen_US
dc.identifier.volume84en_US
dc.identifier.issue1en_US
dc.identifier.startpage62-
dc.identifier.startpage62en_US
dc.identifier.endpage70en_US
dc.authorid0000-0001-7583-6679-
dc.authorid0000-0003-3277-197X-
dc.identifier.doi10.1002/jemt.23565-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid32790124en_US
dc.identifier.scopus2-s2.0-85089369498en_US
dc.identifier.wosWOS:000558789300001en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale University-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
crisitem.author.dept06.01. Clinical Sciences-
crisitem.author.dept06.01. Clinical Sciences-
Appears in Collections:Diş Hekimliği Fakültesi Koleksiyonu
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

5
checked on Nov 21, 2024

Page view(s)

50
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.