Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/38096
Title: | Evaluation of the Effect of Different Curing Units and Exposure Times on Pulp Chamber Temperature Using Simulated Pulpal Microcirculation | Authors: | Ertuğrul, İhsan Furkan Yazkan, Başak |
Keywords: | Curing units; exposure time; pulpal temperature elevation | Publisher: | GALENOS YAYINCILIK | Abstract: | Objective: To compare the elevations in physiological pulp chamber temperature and blood microcirculation during light curing using four different light sources at two different exposure times. Materials and Methods: The study was performed on eighty Class-V cavities divided into eight groups of ten experiments each, according to the curing unit and exposure time. Short-term curing was performed in four groups: quartz-tungsten-halogen (QTH)-20 seconds (s) (XL3000, 3M ESPE, St. Paul, MN, USA); Woodpecker (WP)-15s (Lux V Light Cure Unit, WP, Apexion Dental Products); KR-10s (Demi Plus Dental Curing Light, Kerr Dental) and VL-3s (VALO light-emitting diode Curing Light Xtra Power mode, Ultradent Products, South Jordan, UT, USA). The same units were used for long-term curing at double the exposure time (i.e., CHI-40s, WP-30s, KR-20s, VL-3+3s). Composite material (Filtek Ultimate, 3M/ESPE) was placed into the cavities, followed by light curing performed at a distance of 1 mm. Temperature changes in the pulp chamber were recorded. The Kruskal-Wallis test, followed by Mann-Whitney U multiple comparisons test, were used for statistical analyses, with p<0.001 considered to be statistically significant. Results: There were no significant differences among the curing units at the same exposure times. However, increases in pulp chamber temperatures varied significantly depending on the curing time (p<0.001). All the curing units induced significantly higher intrapulpal temperature changes at long-term curing times, except the WP groups (p<0.001). WP-30s, KR-20s and VL-3+3s exhibited critical temperature increases >5.5 C. Conclusion: Longer curing times led to critical temperature increases in the pulp chamber. Shorter curing times can protect the pulp tissue against damage caused by temperature elevations above a certain threshold. |
URI: | https://hdl.handle.net/11499/38096 https://doi.org/10.4274/meandros.galenos.2019.43255 |
ISSN: | 2149-9063 |
Appears in Collections: | Diş Hekimliği Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
d94e1ac1-77fe-4d73-be22-58d3ea483390.pdf | 754.9 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
48
checked on Aug 24, 2024
Download(s)
14
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.