Title: Isolated seven-level inverter for grid-connected power systems with predictive control method
Authors: Ortatepe, Zafer
Keywords: 7-level (7L) isolated multi-level (MLI) inverter
capacitor voltage balancing
DC-AC power conversion
model predictive control
Transformer Multilevel Inverter
Minimum Number
Topology
Components
Implementation
Design
Publisher: Wiley
Abstract: A novel isolated 7-level (7L) multi-level inverter (MLI) topology for grid-connected medium and high voltage power applications is presented in this paper. The topology consists of two isolated transformers with different winding ratio and four switches connected to a single-phase grid. This topology provides a great advantage over conventional MLIs by reducing passive and active components to allowing a 7L output voltage. Moreover, model predictive control (MPC) method is implemented to 7L-MLI to generate gate signals of switches and ensure capacitor voltage balancing and grid connection. Performance of proposed topology has been confirmed by in-depth analysis under simulation and laboratory setup with existing studies. Experimental results of a 1.5 kW 220 V-rms prototype are presented to support the simulation results. The prototype shows that the harmonic results match the limits of the IEC 61000-3-2 standard and show a better performance for grid connection and capacitor voltage balancing than conventional ones.
URI: https://doi.org/10.1002/cta.3306
https://hdl.handle.net/11499/46775
ISSN: 0098-9886
1097-007X
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Dec 14, 2024

WEB OF SCIENCETM
Citations

2
checked on Dec 20, 2024

Page view(s)

36
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.