Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/46997
Title: | The Effects of Food-Simulating Liquids on Surface Roughness, Surface Hardness, and Solubility of Bulk-Fill Composites | Authors: | Cabadag, Ozge Gizem Gonulol, Nihan |
Keywords: | Bulk-fill composites Food-simulating liquids Solubility Surface hardness Surface roughness Bond Strength Stability Sorption |
Publisher: | Sage Publications India Pvt Ltd | Abstract: | Aim: To investigate the surface roughness, surface hardness, and solubility of bulk-fill composites after exposure to food-simulating liquids (FSLs). Materials and Methods: A total of 200 disc-shaped samples (8 mm diameter x 4 mm depth) were prepared using four bulk-fill composites (SonicFill (TM), Tetric (R) EvoCeram Bulk Fill, Beautifil-Bulk Restorative, Filtek (TM) Bulk Fill Posterior Restorative) and a microhybrid composite (Filtek (TM) Z250) (n = 40). Following the measurement of initial weights of the samples (m(1)), the surface roughness measurements were gauged using a contact-profilometer. The samples were stored in four different FSLs for 7 days, and then the second surface roughness values were recorded. The samples were stored in a desiccator to reach the constant mass and the values were recorded as m(2), then the solubility levels were calculated. The Vickers microhardness values of the samples were determined. A total of 20 specimens were evaluated in terms of surface morphology with a scanning electron microscope (SEM). Data were statistically analyzed with the two-way ANOVA and Bonferroni tests (P < .05). Results: Beautifil-Bulk Restorative was affected at most in terms of surface roughness after storage in FSLs and citric acid caused the highest values in this group (P < .005). Beautifil-Bulk Restorative and Filtek Z250 showed the highest surface hardness values, while the Tetric EvoCeram group had the lowest. The highest solubility values were found in Beautifil-Bulk Restorative, and citric acid and ethanol yielded the highest solubility values for all of the composites. Conclusion: Beautifil-Bulk Restorative is the most affected group in all parameters evaluated and also affected overly by citric acid among the FSLs in consequence of its prereacted glass ionomer fillers. | URI: | https://doi.org/10.1177/2320206820988451 https://hdl.handle.net/11499/46997 |
ISSN: | 2320-2068 2320-2076 |
Appears in Collections: | Diş Hekimliği Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
WEB OF SCIENCETM
Citations
3
checked on Nov 21, 2024
Page view(s)
48
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.