Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/46997
Title: The Effects of Food-Simulating Liquids on Surface Roughness, Surface Hardness, and Solubility of Bulk-Fill Composites
Authors: Cabadag, Ozge Gizem
Gonulol, Nihan
Keywords: Bulk-fill composites
Food-simulating liquids
Solubility
Surface hardness
Surface roughness
Bond Strength
Stability
Sorption
Publisher: Sage Publications India Pvt Ltd
Abstract: Aim: To investigate the surface roughness, surface hardness, and solubility of bulk-fill composites after exposure to food-simulating liquids (FSLs). Materials and Methods: A total of 200 disc-shaped samples (8 mm diameter x 4 mm depth) were prepared using four bulk-fill composites (SonicFill (TM), Tetric (R) EvoCeram Bulk Fill, Beautifil-Bulk Restorative, Filtek (TM) Bulk Fill Posterior Restorative) and a microhybrid composite (Filtek (TM) Z250) (n = 40). Following the measurement of initial weights of the samples (m(1)), the surface roughness measurements were gauged using a contact-profilometer. The samples were stored in four different FSLs for 7 days, and then the second surface roughness values were recorded. The samples were stored in a desiccator to reach the constant mass and the values were recorded as m(2), then the solubility levels were calculated. The Vickers microhardness values of the samples were determined. A total of 20 specimens were evaluated in terms of surface morphology with a scanning electron microscope (SEM). Data were statistically analyzed with the two-way ANOVA and Bonferroni tests (P < .05). Results: Beautifil-Bulk Restorative was affected at most in terms of surface roughness after storage in FSLs and citric acid caused the highest values in this group (P < .005). Beautifil-Bulk Restorative and Filtek Z250 showed the highest surface hardness values, while the Tetric EvoCeram group had the lowest. The highest solubility values were found in Beautifil-Bulk Restorative, and citric acid and ethanol yielded the highest solubility values for all of the composites. Conclusion: Beautifil-Bulk Restorative is the most affected group in all parameters evaluated and also affected overly by citric acid among the FSLs in consequence of its prereacted glass ionomer fillers.
URI: https://doi.org/10.1177/2320206820988451
https://hdl.handle.net/11499/46997
ISSN: 2320-2068
2320-2076
Appears in Collections:Diş Hekimliği Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

WEB OF SCIENCETM
Citations

1
checked on Jul 17, 2024

Page view(s)

32
checked on May 27, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.