Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/50308
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzdemir, Haleen_US
dc.contributor.editorGirişgen, İlknur-
dc.date.accessioned2023-03-10T08:42:14Z-
dc.date.available2023-03-10T08:42:14Z-
dc.date.issued2023en_US
dc.identifier.urihttps://hdl.handle.net/11499/50308-
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=kIrIdtdJ31bRgjb6fHvMUS-TxUPYdzvkNOKW3nFjNMKWLZ9e9-b_4IxlNAKPXjRw-
dc.descriptionBu çalışma Pamukkale Üniversitesi Bilimsel Araştırma Projeleri Koordinasyon Birimi’nin 13/07/2021 tarih ve 13 nolu kararı ile desteklenmiştiren_US
dc.description.abstractÜreteropelvik bileşke darlığı (UPD) klinik olarak anlamlı antenatal hidronefrozların en sık sebebini oluşturmaktadır. İlerleyen dönemlerde kalıcı böbrek hasarına neden olabileceği için UPD’ nin doğru yönetilmesi ve uygun zamanda cerrahi tedavi kararı verilmesi önemlidir. Hastaların takibinde semptomatik olması, hidronefroz derecesi ve böbrekte fonksiyon kaybı gibi durumlar yol gösterici olmaktadır. Ancak hastaların izlem veya cerrahi tedavi kararı (zamanı ve endikasyonları) verilmesi açısından henüz net bir kılavuz yoktur. UPD tanı, takip ve tedavi kararında ultrasonografi (USG) en iyi görüntüleme yöntemidir. USG’ nin yanında nükleer tıp görüntüleme yöntemleri olan mercaptoasetiltriglisin (MAG-3) ve dimerkaptosüksinik asit (DMSA) sintigrafileri hastaların takibinde kullanılmaktadır. Sintigrafik yöntemler ile radyolojik görüntüleme yöntemlerinden farklı olarak separe böbrek fonksiyonları hesaplanabilmektedir. Separe böbrek fonksiyonu toplam böbrek fonksiyonunun her iki böbreğe göre dağılımıdır. Ancak UPD’ de MAG-3 sintigrafisinin separe böbrek fonksiyonlarını olduğundan fazla hesapladığını (supranormal fonksiyon), separe böbrek fonksiyonunu DMSA sintigrafisinin daha doğru gösterdiğini ileri süren çalışmalar mevcuttur. Çalışmamızda UPD’ de separe böbrek fonksiyonlarının belirlenmesinde MAG-3 ve DMSA sintigrafik yöntemlerinin karşılaştırılması hedeflendi. UPD tanılı hastaların izleminde ve separe böbrek fonksiyonunu belirlemede MAG-3 sintigrafisi ile takibin yeterli olup olmadığı, ek olarak DMSA sintigrafisinin çekilmesinin gerekliliğinin sorgulanması amaçlanmıştır. Kliniğimizde son 10 yılda UPD tanısı ile izlenen ve hem MAG-3 hem de DMSA sintigrafisi çekilen hastalar retrospektif olarak incelendi, separe fonksiyonlar sistemden tekrar okundu ve sintigrafi sonuçları, USG bulguları ve tedavi yöntemleri (izlem, piyeloplasti) ile karşılaştırıldı. Separe böbrek fonksiyonları DMSA ve MAG-3 sonuçlarında karşılaştırıldığında UPD olan böbrekte istatiksel olarak anlamlı pozitif yönde kuvvetli düzeyde ilişki bulunmuştur (p=0,0001, r=0,752). Separe böbrek fonksiyonlarının belirlenmesinde MAG-3 ve DMSA sonuçlarının UPD olan böbrekte sınıflaması (supranormal, normal, düşük fonksiyon) yapıldığında %76 oranında tutarlılık mevcuttu ve korelasyon göstermekteydi. Uyum incelemesi p=0,0001/k=0,456 idi. MAG-3’ te 2 hastada supranormal fonksiyon, 13 hastada düşük fonksiyon var iken DMSA’ da 5 hastada supranormal fonksiyon, 8 hastada düşük fonksiyon mevcuttu. DMSA’ da supranormal fonksiyon oranı MAG-3’ e göre daha yüksek idi. MAG-3 ise düşük fonksiyonlu olan böbrekleri DMSA’ ya göre daha fazla tespit etmişti. Literatürdekinin aksine MAG-3 sintigrafisinin supranormal ölçüm oranını düşük saptadık. Ayrıca separe böbrek fonksiyonu açısından supranormal fonksiyon ölçülmesi nedenini ve etkileyen faktörler açısından incelenen verilerle (böbrek boyutları, parankim incelmesi, böbrek pelvis anterior-posterior çap) supranormal fonksiyon arasında ilişki değerlendirildi. Artmış böbrek boyutunun DMSA’ da ki supranormal fonksiyon ile anlamlı ilişkisi saptanmışken diğer parametrelerin DMSA ve MAG-3 sintigrafisinde supranormal fonksiyon üzerine etkisi saptanmamıştır. Ancak bu durum supranormal ölçülen hasta sayımızın azlığı ile ilişkili olabilir. Çalışmamızın sonuçları bize her UPD’ de her iki sintigrafik yöntemin kullanılmasına gerek olmadığını, MAG-3 ile takibin yeterli olabileceğini, DMSA’ nın kortikal defekt şüphesi olan ya da operasyon kararı verilen hastalarda bazal kortikal fonksiyonu belirlemek amacı ile operasyon öncesi çekilebileceğini düşündürdü.en_US
dc.description.abstractUreteropelvic junction obstruction (UPJO) is the most common cause of clinically significant antenatal hydronephrosis. Since it may cause permanent kidney damage in the future, it is crucial to manage UPJO correctly and decide on surgical treatment at the appropriate time. Conditions such as symptomatic status, degree of hydronephrosis, and loss of function in the kidney are guiding factors in the follow-up of patients. However, there is no clear guideline for the patients' follow-up or surgical treatment decision (time and indications). Ultrasonography (USG) is the best imaging method for the diagnosis, follow-up, and treatment decision of UPJO. In addition to USG, mercaptoacetyltriglycine (MAG-3) and dimercaptosuccinic acid (DMSA) scintigraphies, which are nuclear medicine imaging methods, are used in the follow-up of patients. Differential renal function can be calculated with scintigraphic methods, unlike radiological imaging methods. Differential renal function is the distribution of total kidney function by both kidneys. However, studies suggest that MAG-3 scintigraphy overestimates the differential renal function (supranormal function) in UPJO and that DMSA scintigraphy shows the differential renal function more accurately. Our study aimed to compare MAG-3 and DMSA scintigraphic methods in determining differential renal function in UPJO. It aimed to question whether follow-up with MAG-3 scintigraphy was sufficient in the follow-up of patients with UPJO and to determine kidney function and the necessity of DMSA scintigraphy. The patients who were followed up with the diagnosis of UPJO in our clinic in the last ten years and who had both MAG-3 and DMSA scintigraphy were analyzed retrospectively, the differential functions were reexamined from the system, and the results of the scintigraphy, USG findings, and treatment approaches (non-surgical management, pyeloplasty) were compared. When differential renal function were compared in DMSA and MAG-3 results, a statistically significant positive and strong correlation was found in the kidney with UPJO (p=0.0001, r=0.752). When the MAG-3 and DMSA results were classified in the kidney with UPJO (supranormal, normal, low function) in the determination of differential renal functions, there was a consistency of 76%, and it was correlated. The kappa coefficent was p=0.0001/k=0.456. While two patients had a supranormal function and 13 patients had a low function in MAG-3, five patients had a supranormal function, and eight patients had a low function in DMSA. The rate of supranormal function in DMSA was higher than that in MAG-3. MAG-3 detected low-functioning kidneys more frequently than DMSA. Contrary to the literature, we found that the supranormal measurement rate of MAG-3 scintigraphy was low. In addition, the reason for measuring supranormal function in terms of differential renal function and the relationship between the analyzed data in terms of affecting factors (kidney size, parenchymal thinning, renal pelvis anterior- posterior diameter) and supranormal function were evaluated. While increased kidney size was significantly associated with supranormal function in DMSA, no effect of other parameters on supranormal function was found in DMSA and MAG-3 scintigraphy. However, this may be related to the small number of patients measured supranormal. The results of our study suggested that there is no need to use both scintigraphic methods in each UPJO, that follow-up with MAG-3 may be sufficient, in patients with cortical defect suspicion or surgery decision DMSA may be taken before the operation in order to determine the basal cortical function.en_US
dc.language.isotren_US
dc.publisherPamukkale Üniversitesi Tıp Fakültesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectÜreteropelvik bileşke darlığıen_US
dc.subjectSepare böbrek fonksiyonuen_US
dc.subjectSupranormal fonksiyonen_US
dc.subjectMAG-3, DMSAen_US
dc.subjectUreteropelvic junction obstructionen_US
dc.subjectdifferential renal functionen_US
dc.subjectSupranormal functionen_US
dc.subjectMAG-3, DMSAen_US
dc.titleÜreteropelvik bileşke darlığında separe böbrek fonksiyonlarını belirlemede MAG-3- DMSA sintigrafik yöntemlerinin karşılaştırılmasıen_US
dc.title.alternativeComparison of MAG-3-DMSA scintigraphic methods in determining differential renal function in ureteropelvic junction obstructionen_US
dc.typeSpecialist Thesisen_US
dc.relation.publicationcategoryTezen_US
dc.identifier.yoktezid779862en_US
item.languageiso639-1tr-
item.openairetypeSpecialist Thesis-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept14.02. Internal Medicine-
Appears in Collections:Tıp Fakültesi Tez Koleskiyonu
Files in This Item:
File Description SizeFormat 
hale_ozdemir_tez.pdf1.9 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

636
checked on May 27, 2024

Download(s)

310
checked on May 27, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.