Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/51272
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElçi, S.G.-
dc.date.accessioned2023-06-13T19:15:39Z-
dc.date.available2023-06-13T19:15:39Z-
dc.date.issued2022-
dc.identifier.issn0306-7319-
dc.identifier.urihttps://doi.org/10.1080/03067319.2020.1747615-
dc.identifier.urihttps://hdl.handle.net/11499/51272-
dc.description.abstractA magnetic solid-phase extraction using magnetite coated with polyaniline-polythiophene copolymer (Fe3O4@coPANI-PTH) was applied for preconcentration of Ni(II) and Cu(II) in some soft drinks and spice samples followed by microsample injection system-flame atomic absorption spectrometry (MIS-FAAS). Preconcentration optimisations including pH, amount of adsorbent, eluent type and volume, sample volume, interfering ion effects were investigated. Relative recoveries of 85.2–96.8% were satisfactorily obtained by extracting both analytes from 50 mL sample solution buffered at pH 10 to 0.5 mL eluent using 100 mg Fe3O4@coPANI-PTH. Good linearity was obtained ranging from 5 to 80 µg L−1 with a regression coefficient of 0.999. Limits of detection for Ni(II) and Cu(II) were 2.8 and 1.2 µg L−1, respectively. The accuracy of the method was confirmed by the analysis of certified reference samples and real samples spiked with the analytes. The relative error and standard deviation of the current method for both analytes were smaller than 6%. The established method was applied to commercially available some local soft drinks and spice samples. © 2020 Informa UK Limited, trading as Taylor & Francis Group.en_US
dc.description.sponsorshipPamukkale Üniversitesi, PAÜ: 2018HZDP057en_US
dc.description.sponsorshipThe research was supported by the scientific research projects coordination unit of Pamukkale University [Project number: 2018HZDP057]. The author would like to thank Prof. Dr Latif ELCI for allowing access to use instrumentation available in his research laboratory. The author would like to thank Prof. Dr Mustafa SOYLAK for BET and AFM analysis and their interpretation of the results.en_US
dc.language.isoenen_US
dc.publisherTaylor and Francis Ltd.en_US
dc.relation.ispartofInternational Journal of Environmental Analytical Chemistryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectcopperen_US
dc.subjectFe3O4@coPANI-PTHen_US
dc.subjectMIS-FAASen_US
dc.subjectnickelen_US
dc.subjectsoft drinken_US
dc.subjectspice samplesen_US
dc.subjectAbsorption spectroscopyen_US
dc.subjectAtomic absorption spectrometryen_US
dc.subjectBeveragesen_US
dc.subjectCopper compoundsen_US
dc.subjectIron oxidesen_US
dc.subjectMagnetiteen_US
dc.subjectNickel compoundsen_US
dc.subjectPhase separationen_US
dc.subjectPolyanilineen_US
dc.subjectSPICEen_US
dc.subjectFlame atomic absorption spectrometric determinationen_US
dc.subjectFlame atomic absorption spectrometryen_US
dc.subjectLimits of detectionen_US
dc.subjectMagnetic solid-phase extractionsen_US
dc.subjectPolythiophene copolymersen_US
dc.subjectPre-concentrationen_US
dc.subjectRegression coefficienten_US
dc.subjectStandard deviationen_US
dc.subjectExtractionen_US
dc.titleA magnetic solid-phase extraction method using Fe3O4@coPANI-PTH for microsample injection system-flame atomic absorption spectrometric determination of nickel and copper in soft drinks and spice samplesen_US
dc.typeArticleen_US
dc.identifier.volume102en_US
dc.identifier.issue9en_US
dc.identifier.startpage2038en_US
dc.identifier.endpage2052en_US
dc.departmentPamukkale Universityen_US
dc.identifier.doi10.1080/03067319.2020.1747615-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55270116200-
dc.identifier.scopus2-s2.0-85083838275en_US
dc.institutionauthor-
dc.identifier.scopusqualityQ3-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
crisitem.author.dept20.03. Biomedical Engineering-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

18
checked on Nov 16, 2024

Page view(s)

54
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.