dc.description.abstract | A magnetic solid-phase extraction using magnetite coated with polyaniline-polythiophene copolymer (Fe3O4@coPANI-PTH) was applied for preconcentration of Ni(II) and Cu(II) in some soft drinks and spice samples followed by microsample injection system-flame atomic absorption spectrometry (MIS-FAAS). Preconcentration optimisations including pH, amount of adsorbent, eluent type and volume, sample volume, interfering ion effects were investigated. Relative recoveries of 85.2–96.8% were satisfactorily obtained by extracting both analytes from 50 mL sample solution buffered at pH 10 to 0.5 mL eluent using 100 mg Fe3O4@coPANI-PTH. Good linearity was obtained ranging from 5 to 80 µg L−1 with a regression coefficient of 0.999. Limits of detection for Ni(II) and Cu(II) were 2.8 and 1.2 µg L−1, respectively. The accuracy of the method was confirmed by the analysis of certified reference samples and real samples spiked with the analytes. The relative error and standard deviation of the current method for both analytes were smaller than 6%. The established method was applied to commercially available some local soft drinks and spice samples. © 2020 Informa UK Limited, trading as Taylor & Francis Group. | en_US |
dc.description.sponsorship | Pamukkale Üniversitesi, PAÜ: 2018HZDP057 | en_US |
dc.description.sponsorship | The research was supported by the scientific research projects coordination unit of Pamukkale University [Project number: 2018HZDP057]. The author would like to thank Prof. Dr Latif ELCI for allowing access to use instrumentation available in his research laboratory. The author would like to thank Prof. Dr Mustafa SOYLAK for BET and AFM analysis and their interpretation of the results. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Taylor and Francis Ltd. | en_US |
dc.relation.ispartof | International Journal of Environmental Analytical Chemistry | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | copper | en_US |
dc.subject | Fe3O4@coPANI-PTH | en_US |
dc.subject | MIS-FAAS | en_US |
dc.subject | nickel | en_US |
dc.subject | soft drink | en_US |
dc.subject | spice samples | en_US |
dc.subject | Absorption spectroscopy | en_US |
dc.subject | Atomic absorption spectrometry | en_US |
dc.subject | Beverages | en_US |
dc.subject | Copper compounds | en_US |
dc.subject | Iron oxides | en_US |
dc.subject | Magnetite | en_US |
dc.subject | Nickel compounds | en_US |
dc.subject | Phase separation | en_US |
dc.subject | Polyaniline | en_US |
dc.subject | SPICE | en_US |
dc.subject | Flame atomic absorption spectrometric determination | en_US |
dc.subject | Flame atomic absorption spectrometry | en_US |
dc.subject | Limits of detection | en_US |
dc.subject | Magnetic solid-phase extractions | en_US |
dc.subject | Polythiophene copolymers | en_US |
dc.subject | Pre-concentration | en_US |
dc.subject | Regression coefficient | en_US |
dc.subject | Standard deviation | en_US |
dc.subject | Extraction | en_US |
dc.title | A magnetic solid-phase extraction method using Fe3O4@coPANI-PTH for microsample injection system-flame atomic absorption spectrometric determination of nickel and copper in soft drinks and spice samples | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 102 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.startpage | 2038 | en_US |
dc.identifier.endpage | 2052 | en_US |
dc.department | Pamukkale University | en_US |
dc.identifier.doi | 10.1080/03067319.2020.1747615 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 55270116200 | - |
dc.identifier.scopus | 2-s2.0-85083838275 | en_US |
dc.institutionauthor | … | - |
dc.identifier.scopusquality | Q3 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 20.03. Biomedical Engineering | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Teknoloji Fakültesi Koleksiyonu |
CORE Recommender
SCOPUSTM
Citations
18
checked on Nov 16, 2024
Page view(s)
54
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.