Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/52481
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAkbaş, Bülenten_US
dc.contributor.authorHüner, İbrahimen_US
dc.date.accessioned2023-09-28T10:52:09Z-
dc.date.available2023-09-28T10:52:09Z-
dc.date.issued2023en_US
dc.identifier.urihttps://hdl.handle.net/11499/52481-
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=S2eMu1TIwY_v4mYv58xAr1S0SpE678S20ZhBH3cnmiTNNJd-fTLiVHHuXG7H44aQ-
dc.description.abstractGeçmiş depremlerde sıvı depolama tanklarında meydana gelen hasarlar; tankların sismik davranışının deneysel ve analitik olarak incelenmesini zorunlu kılmıştır. Bu çalışma, farklı tipteki taban izolatör sistemlerinin Sıvılaştırılmış Doğal Gaz depolama tanklarının sismik performansı üzerindeki etkisini araştırmaktadır. Sabit mesnetli ve üç farklı sismik yalıtımlı tankların zaman tanım alanında doğrusal olmayan dinamik analizleri, Deprem Yer Hareketi-1’e (DD-1) göre ölçeklenen 7 farklı yer hareketinin ortalama ivmesi için gerçekleştirilmiştir. İzolatör tipi olarak yüksek sönümlemeli kauçuk, kurşun çekirdekli kauçuk ve sürtünmeli sarkaç sistemleri gözönüne alınmıştır. Bu izolatörler, deneysel verilere dayalı kuvvet-yer değiştirme ilişkilerine sahip doğrusal olmayan yaylar olarak modellenmiştir. LNG sıvısı, çelik tank, dış kabuk, betonarme çevre kirişi, çatı, temel betonu, alt ve yan duvar izolasyonlarının modelleme çalışmalarında ANSYS Workbench programı; LNG sıvısı, çelik tank ve temel betonunun lineer olmayan analizi için LS-DYNA programı kullanılmıştır. Sabit mesnetli ve üç farklı sismik yalıtımlı tankların toplam taban kesme kuvveti, çalkalanma yüksekliği, çelik tank gerilmeleri, çelik tank kabuk levhası yanal deformasyonu, çelik tank taban ve duvarın en üst noktasındaki deplasmanları, izolatör yatay kuvvet-yer değiştirmeleri ve izolatöre gelen düşey kuvvetler karşılaştırılmıştır. Sonuçlar, sabit ve izolatörlü sistemlerde modlar arasında fark olmadığını göstermektedir. Sıvının dalga hareketinin yapının salınımından farklı hareket ettiği ve izolatörlerin çalkalanma hareketini etkilemediği sonucuna varılmıştır. Sismik yalıtımlı tankların taban kesme kuvvetleri ve çelik tank gerilmelerinin sabit mesnetlilere göre sırasıyla %50-70 ve %85-95 arasında azaldığı görülmüştür. Fakat çalkalanma yüksekliklerinde bir değişiklik söz konusu değildir. İzolatörlü sistemlerin 400mm’ye varan yatay deplasman hareketi ise tanka bağlanan mekanik techizat ve borular açısından tehlike arz etmektedir.en_US
dc.description.abstractDamages in liquid storage tanks in past earthquakes; This necessitated the experimental and analytical investigation of the seismic behavior of the tanks. This study investigates the effect of different types of base isolator systems on the seismic performance of Liquefied Natural Gas storage tanks. Nonlinear time history analyses of fixed support and three different seismic isolated tanks were performed for the average acceleration of 7 different ground motions scaled according to Earthquake Ground Motion-1 (DD-1). High damping rubber, lead core rubber and friction pendulum systems are considered as insulator types. These insulators are modeled as nonlinear springs with force-displacement relationships based on experimental data. ANSYS Workbench program in modeling studies of LNG liquid, inner steel tank, outer shell, reinforced concrete ring beam, roof, foundation concrete, bottom and side wall insulations; LS-DYNA program was used for non-linear analysis of LNG liquid, inner steel tank and foundation concrete. Total bottom shear force, sloshing height, steel tank stresses, steel tank shell plate lateral deformation, steel tank bottom and wall displacements, insulator horizontal force-displacements, and vertical forces on the insulator of tanks with fixed support and three different seismic insulation were compared. The results show that there is no difference between modes in fixed and isolator systems. It was concluded that the wave motion of the liquid acts differently from the oscillation of the structure and does not affect the agitation motion of the insulators. It has been observed that the bottom shear forces and steel tank stresses of the seismic insulated tanks are reduced by 50-70% and 85- 95%, respectively, compared to the fixed supports. However, there is no change in agitation heights. Horizontal displacement of isolator systems up to 400mm poses a danger to the mechanical equipment and pipes connected to the tank.en_US
dc.language.isotren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLng depolama tanklarıen_US
dc.subjectansys workbenchen_US
dc.subjectdoğrusal olmayan anali̇zen_US
dc.subjectHDRBen_US
dc.subjectLRBen_US
dc.subjectFPSen_US
dc.subjectLS-DYNAen_US
dc.subjectLng storage tanksen_US
dc.subjectWorkbenchen_US
dc.subjectnon-lineer analysesen_US
dc.titleDoğrusal olmayan analiz ile deprem yükleri altında taban izolatörlü LNG tankların davranışlarının karşılaştırılmasıen_US
dc.title.alternativeComparision of the behavior of lng tanks with seismic isolators under earthquake loads with nonlinear analysisesen_US
dc.typeDoctoral Thesisen_US
dc.departmentPAÜ, Enstitüler, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US
dc.identifier.yoktezid830486en_US
dc.description.startpage1en_US
dc.description.endpage269en_US
item.languageiso639-1tr-
item.openairetypeDoctoral Thesis-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:Tez Koleksiyonu
Files in This Item:
File Description SizeFormat 
10575655.pdf13.26 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

102
checked on May 27, 2024

Download(s)

232
checked on May 27, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.