Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/56588
Title: Polipirol kaplı Fe3O4 nanotanecik kullanImIyla eser düzeydeki bazI elementlerin zenginleştirilmesi ve AAS ile tayinleri
Other Titles: Enrichment of some trace elements with the use of Fe3O4 nanoparticles coated with polypyrrole and their determination by AAS
Authors: Sağnak, Elif
Advisors: Höl, Ayşen
Keywords: Polipirol kaplı Fe3O4 Nanotanecik
Manyetik Katı Faz Ekstraksiyonu
Atomik Absorpsiyon Spektrometresi
Ağır metal
Polypyrole coated Fe3O4 Nanoparticle
Magnetic Solid Phase Extraction
Atomic Absorption Spectrometry
Heavy Metal
Abstract: Bu tez çalışmasında eser miktardaki bakır, kobalt, nikel, çinko, kurşun, kadminyum ve krom iyonlarının tayinleri için yeni bir manyetik katı faz ekstraksiyonu (MSPE) metodu geliştirildi. Yöntemde adsorban olarak, 0,05 g sentezi yapılan polipirol ile kaplanmış Fe3O4 manyetik nanoparçacıklar (Fe3O4@PPy MNP) kullanıldı. Manyetik katı faz ekstraksiyonu ile önderiştirilen analitler alevli atomik absorpsiyon spektrometresi ile tayin edildi. 0,05 g polipirol kaplı Fe3O4 katı faz materyali olarak kullanılmıştır. Pb(II), Cu(II), Cd(II), Cr(II), Ni(II), Zn(II), Pb(II) ve Co(II) iyonlarının kantitatif alıkonmaları pH 7,5’da elde edildi. Belirlenen iyonların tayini için maksimum örnek hacimleri sırasıyla, Cr(II), Cu(II), Pb(II) için 10 mL, Co(II), Zn(II) için 50 mL, Ni(II), Cd(II) 150 mL olarak hesaplandı. Bütün iyonlar 1M HNO3 ile kantitatif olarak elüe edildi.
In this thesis study, a new magnetic solid phase extraction (MSPE) method was developed for the determination of trace amounts of copper, cobalt, nickel, zinc, lead, cadmium and chromium ions. In the method, 0,05 g of synthesized polypyrrole-coated Fe3O4 magnetic nanoparticles (Fe3O4@PPy MNP) were used as adsorbents. Analytes preconcentrated by magnetic solid phase extraction were determined by flame atomic absorption spectrometry. 0.05 g polypyrrole-coated Fe3O4 was used as solid phase material.Quantitative retentions of Pb(II), Cu(II), Cd(II), Cr(II), Ni(II), Zn(II), Pb(II) and Co(II) ions were obtained at pH 7.5. Maximum sample volumes for the determination of the specified ions are respectively: 10 mL for Cr(II), Cu(II), Pb(II), 50 mL for Co(II), Zn(II), 150 mL for Ni(II), Cd(II). It was calculated in mL. All ions were eluted quantitatively with 1M HNO3.
Description: Bu tez çalışması Pamukkale Üniversitesi Bilimsel Araştırma Projeleri Birimi tarafından 2022 FBE021 nolu proje ile desteklenmiştir.
URI: https://hdl.handle.net/11499/56588
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
10378605.pdf8.25 MBAdobe PDFView/Open
Tezlerin erisime acilmasi ve kisitlanmasi (Elif SAGNAK) (1).pdf
  Restricted Access
482.95 kBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

Page view(s)

88
checked on Aug 24, 2024

Download(s)

12
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.