dc.description14th International Conference on Electrical and Electronics Engineering, ELECO 2023 -- 30 November 2023 through 2 December 2023 -- 197135en_US
dc.description.abstractElectrosurgery is a medical device that provides a thermal effect using high frequency current. When the tissue load changes over a broad scale during surgery, it should maintain a constant output power, that mean the broad output and high frequency voltage must be supplied by electrosurgery. In this study, class D resonant inverter design based on GaN is presented for electrosurgery. Due to its resonant nature, the inverter is convenient for broad scale voltage regulation and inverter switches provide ZVS (Zero Voltage Switching) operation. The technical analysis and simulation result of the proposed class D resonant inverter for different cutting modes are given. As a result, it is aimed to design an electrosurgery with high efficiency and high frequency. © 2023 IEEE.en_US
dc.description.sponsorshipPamukkale Üniversitesi, PAÜ: 2022FEBE042en_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartof14th International Conference on Electrical and Electronics Engineering, ELECO 2023 - Proceedingsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEfficiencyen_US
dc.subjectElectric invertersen_US
dc.subjectVoltage regulatorsen_US
dc.subjectZero voltage switchingen_US
dc.subjectClass D resonant inverteren_US
dc.subjectConstant output poweren_US
dc.subjectGaN baseden_US
dc.subjectHigh-frequency currenten_US
dc.subjectHigh-frequency inverteren_US
dc.subjectHigh-frequency voltageen_US
dc.subjectLoad changeen_US
dc.subjectMedical Devicesen_US
dc.subjectOutput frequencyen_US
dc.subjectPerformances evaluationen_US
dc.subjectGallium nitrideen_US
dc.titleEfficiency Performance Evaluation of A Second Stage GaN Based High Frequency Inverter for Electrosurgeryen_US
dc.typeConference Objecten_US
dc.departmentPamukkale Universityen_US
dc.identifier.doi10.1109/ELECO60389.2023.10416039-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.authorscopusid58903478400-
dc.authorscopusid16024076700-
dc.identifier.scopus2-s2.0-85185823739en_US
dc.institutionauthor-
item.languageiso639-1en-
item.openairetypeConference Object-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept20.03. Biomedical Engineering-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
Show simple item record



CORE Recommender

Page view(s)

22
checked on May 27, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.