Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/57400
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTarınç, Hale-
dc.contributor.authorÇetin, Sevilay-
dc.date.accessioned2024-06-29T13:49:31Z-
dc.date.available2024-06-29T13:49:31Z-
dc.date.issued2024-
dc.identifier.issn1302-0900-
dc.identifier.issn2147-9429-
dc.identifier.urihttps://doi.org/10.2339/politeknik.1424645-
dc.identifier.urihttps://hdl.handle.net/11499/57400-
dc.description.abstractAim The aim of this work is to design a GaN-based high -frequency full -bridge class DE resonant inverter topology for electrosurgery. Design & Methodology High -frequency and wide load range are taken into consideration in the design procedure. The selected switching frequency is 500 kHz. Variable loads are applied to the designed inverter and measurements are taken. . Originality In this study, a high -frequency full -bridge class DE resonant inverter operating in a wide load range for three modes of electrosurgery applications is designed. Findings The presented design is verified on a prototype and results are obtained for all three modes, pure cutting, blend, and coagulation, at variable loads. In addition, studies have been carried out on a different load simulating real tissue for all three modes. Conclusion A high -frequency inverter design operating at wide load range has been obtained for electrosurgery. On the potato load for pure cutting mode, an output voltage of 39.9 V and an output current of 0.7 A while the efficiency is around 35%.en_US
dc.description.sponsorshipPamukkale University [2022FEBE042]en_US
dc.description.sponsorshipThis work is supported by Pamukkale University under grant number 2022FEBE042.en_US
dc.language.isoenen_US
dc.publisherGazi Univen_US
dc.relation.ispartofJournal of Polytechnic-Politeknik Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectelectrosurgeryen_US
dc.subjecthigh frequencyen_US
dc.subjectGaNen_US
dc.subjectresonant inverteren_US
dc.titleDesign of a gan-based high-frequency inverter for electrosurgeryen_US
dc.typeArticleen_US
dc.typeArticle; Early Accessen_US
dc.departmentPamukkale Universityen_US
dc.identifier.doi10.2339/politeknik.1424645-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.wosWOS:001229339200001en_US
dc.institutionauthor-
item.cerifentitytypePublications-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.openairetypeArticle-
item.openairetypeArticle; Early Access-
item.grantfulltextopen-
crisitem.author.dept20.03. Biomedical Engineering-
Appears in Collections:Teknoloji Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
10.2339-politeknik.1424645-3679856.pdf1.24 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

24
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.