Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/57937
Title: Magnetic solid-phase extraction technique based on Fe3O4@coPPy-PTH nanocomposite for extraction of cobalt, chromium, and nickel prior to determination by microsample injection system-flame atomic absorption spectrometry in alcoholic and nonalcoholic beverages
Authors: Küçüksakalli, M.
Salamat, Q.
Tırelı, B.
Elçı, Ş.G.
Keywords: beer
Fe<sub>3</sub>O<sub>4</sub>@coPPy-PTH nanocomposite
metal ions
microsample injection system-flame atomic absorption spectrometry
wine
Publisher: TUBITAK
Abstract: A novel Fe3O4@coPPy-PTH nanocomposite-based sorbent was prepared via in situ oxidative polymerization using Fe3O4 nanoparticles with spherical and flower-like morphologies of thiophene and pyrrole as the feedstocks. The synthesized nanocomposite displayed sensitive extraction and determination of metal ions Co(II), Cr(III), and Ni(II) without a chelating agent, followed by microsample injection system-flame atomic absorption spectrometry. Advanced spectroscopic and imaging techniques including scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy were used to characterize the composition and morphology of the Fe3O4@coPPy-PTH nanocomposite. SEM observations showed that the size of the Fe3O4 nanoparticles changed from 30 nm to 120 nm in diameter after copolymer (PPy-PTH) coating. The Fe3O4@coPPy-PTH nanocomposite has good dispersion properties and stability in strong acid solutions. For effective extraction of the studied analytes, the influence of sample pH, volume of sample solution and eluent, amount of adsorbent, and interference of coexisting metal ions were optimized. Under the optimum conditions, preconcentration factors were obtained as 25 for all analytes. The calibration curves were linear in the range of 0.0–10.0 µg L–1 with coefficients of determination (R2) greater than 0.9957 for all three analytes. Limits of detection (S/N = 3) were calculated in the range of 0.17–0.23 µg L–1. Precision values, expressed as relative standard deviations, were lower than 3.0%, and relative recoveries were obtained in the range of 88.6%–103.6%. The proposed method (Fe3O4@coPPy-PTH/MSPE/MIS-FAAS) was successfully applied to extract and determine the studied metal ions in beer, wine, and nonalcoholic beverage samples. © 2024 TUBITAK. All rights reserved.
URI: https://doi.org/10.55730/1300-0527.3683
https://hdl.handle.net/11499/57937
ISSN: 1300-0527
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
Magnetic solid-phase extraction technique based on Fe3O4@coPPy-PT.pdf989.62 kBAdobe PDFView/Open
Show full item record



CORE Recommender

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.