Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/59291
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yenidünya, Ö.G. | - |
dc.contributor.author | Erdem, A. | - |
dc.contributor.author | Akgül, N. | - |
dc.contributor.author | Yazkan, B. | - |
dc.contributor.author | Özcan, M. | - |
dc.date.accessioned | 2025-03-22T21:38:04Z | - |
dc.date.available | 2025-03-22T21:38:04Z | - |
dc.date.issued | 2025 | - |
dc.identifier.issn | 2822-2555 | - |
dc.identifier.uri | https://doi.org/10.17567/currresdentsci.1617446 | - |
dc.identifier.uri | https://hdl.handle.net/11499/59291 | - |
dc.description.abstract | Objective: To evaluate the effects of preheating procedure and polymerization modes on degree of conversion (DC) of resin composites. Methods: Three different types of composites-a conventional (GrandioSO-[GSO]), a bulkfill (GrandioSO x-tra-[GSX]), and a thermoviscous bulkfill (VisCalor bulk-[VCB])-were investigated. Three specimens were prepared for each combination of the variables (composite type*preheating procedure*polymerization mode). Photo-polymerization was performed using an LED operated in standard (SM), high power plus (HM), and x-tra power (XM) modes. DC was measured with Fourier Transform Infrared Spectroscopy after 5 min and 24 h post-irradiation. Furthermore, three-way analysis of variance followed by a Tukey test at a significance level of P <.05 were performed to compare the DC values. Results: Considering the DC values at two post-irradiation time, preheated VCB group polymerized with HM gave the highest DC value, while GSX cured with XM, regardless of the preheating exhibited the lowest one. Preheating application caused a statistically significant increase in the DC values of the VCB*SM, VCB*HM, and GSO*HM groups at both evaluation periods, and the GSX*SM group at 24h post-irradiation. Regarding the polymerization mode, the ranking depending on the significant differences among all preheated composites tested at both time intervals was HM > SM > XM. Conclusion: Preheating generally exhibited favorable effects on the DC of all tested composites, with the most significant impact observed in VCB. Additionally, polymerization with x-tra power mode is not recommended to achieve a sufficient DC required for clinically acceptable restorations. © 2025, Ataturk Universitesi. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Ataturk Universitesi | en_US |
dc.relation.ispartof | Current Research in Dental Sciences | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Bulk Fill Composite | en_US |
dc.subject | Degree Of Conversion | en_US |
dc.subject | Ftir | en_US |
dc.subject | Polymerization Mode | en_US |
dc.subject | Preheating | en_US |
dc.subject | Thermoviscousity | en_US |
dc.title | Influence Of Preheating Procedure And Polymerization Modes On Degree Of Conversion Of Contemporary Resin Composites | en_US |
dc.title.alternative | Ön Isıtma İşlemi ve Polimerizasyon Modlarının Güncel Rezin Kompozitlerin Dönüşüm Derecesi Üzerindeki Etkisi | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 35 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 65 | en_US |
dc.identifier.endpage | 70 | en_US |
dc.department | Pamukkale University | en_US |
dc.identifier.doi | 10.17567/currresdentsci.1617446 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 58647796100 | - |
dc.authorscopusid | 59588410300 | - |
dc.authorscopusid | 6506373608 | - |
dc.authorscopusid | 55846061700 | - |
dc.authorscopusid | 7102067681 | - |
dc.identifier.scopus | 2-s2.0-85218466146 | - |
dc.identifier.scopusquality | Q4 | - |
dc.identifier.wosquality | N/A | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 06.01. Clinical Sciences | - |
crisitem.author.dept | 06.01. Clinical Sciences | - |
crisitem.author.dept | 06.01. Clinical Sciences | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.