Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/6184
Title: Investigation of the starting performance of damper coiled salient pole synchronous generator with different slot design
Authors: Öner, Yusuf
Keywords: 2D magnetic analysis
Salient pole synchronous generator
Transient analysis
Wind generator design
Abstract: Starting performance of synchronous generators and the time in which the machine comes into steady state are important. Hence, there is much research carried out on the starting performance of synchronous generators. The more the power of the synchronous generator is, the more important its starting performance becomes. In the present study, through Ansoft Maxwell program, the design of 2.2 MW and 6600v synchronous generators was made, and then two-dimensional static magnetic analyses and two-dimensional transient analyses were performed. In this way, we were able to investigate starting losses, period of coming to steady state, phase currents and instantaneous torque values of the synchronous generators. ©2010 Academic Journals.
URI: https://hdl.handle.net/11499/6184
ISSN: 1992-2248
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Oct 13, 2024

WEB OF SCIENCETM
Citations

1
checked on Nov 16, 2024

Page view(s)

34
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.