Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/7662
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Iça, R.B. | - |
dc.contributor.author | Öztürkb, F. | - |
dc.contributor.author | Ateş, Burhan | - |
dc.contributor.author | Malkocd, M.A. | - |
dc.contributor.author | Kelestemur, Ü. | - |
dc.date.accessioned | 2019-08-16T12:31:12Z | |
dc.date.available | 2019-08-16T12:31:12Z | |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0003-3219 | - |
dc.identifier.uri | https://hdl.handle.net/11499/7662 | - |
dc.identifier.uri | https://doi.org/10.2319/060713-435.1 | - |
dc.description.abstract | Objective: To quantify, with high-pressure liquid chromatography (HPLC), the amount of residual monomer leached from different orthodontic acrylic materials prepared with two different manipulation methods. Materials and Methods: Eighty cylindrical specimens (5 × 25 mm) were divided into eight groups (n = 10). The specimens were prepared with four acrylic materials-Orthocryl Neon Blue (Dentaurum), Orthocryl EQ (Dentaurum), Orthoplast (Vertex), and O-80 (Imicryl)-and with two different manipulation methods: doughing and spray-on. HPLC measurements were made at intervals of 2 hours, 6 hours, 1 day, 1 week, and 3 months. One-way analysis of variance (ANOVA) and Tukey's honestly significant difference multiple-comparison test were used to assess the amount of monomer eluted from the various groups. To assess the differences within each group over the various periods, repeated-measures ANOVA and paired t-tests were used. Results: Statistically significant differences were found within the groups in the amount of residual monomer in the specimens at different time intervals (P < .001). HPLC showed statistically significant differences among the groups (P < .05) in the amount of eluted monomer. Evaluation of the manipulation techniques showed that the monomer release rate was higher in the specimens prepared with the doughing method. When the four acrylic materials were compared, the specimens made from Orthoplast (Vertex) showed the highest rate of monomer release with both manipulation techniques. Conclusion: The spray-on method can be recommended to clinicians for the preparation of orthodontic appliances. © 2014 by The EH Angle Education and Research Foundation, Inc. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Allen Press Inc. | en_US |
dc.relation.ispartof | Angle Orthodontist | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Acrylic material | en_US |
dc.subject | Manipulation methods | en_US |
dc.subject | Monomer release | en_US |
dc.subject | acrylic acid resin | en_US |
dc.subject | aerosol | en_US |
dc.subject | cross linking reagent | en_US |
dc.subject | dental material | en_US |
dc.subject | ethylene glycol dimethacrylate | en_US |
dc.subject | methacrylic acid derivative | en_US |
dc.subject | methacrylic acid methyl ester | en_US |
dc.subject | Orthocryl | en_US |
dc.subject | orthoplast | en_US |
dc.subject | poly(methyl methacrylate) | en_US |
dc.subject | polymer | en_US |
dc.subject | terpene | en_US |
dc.subject | chemistry | en_US |
dc.subject | comparative study | en_US |
dc.subject | high performance liquid chromatography | en_US |
dc.subject | human | en_US |
dc.subject | materials testing | en_US |
dc.subject | orthodontic device | en_US |
dc.subject | polymerization | en_US |
dc.subject | temperature | en_US |
dc.subject | time | en_US |
dc.subject | viscosity | en_US |
dc.subject | Acrylic Resins | en_US |
dc.subject | Aerosols | en_US |
dc.subject | Chromatography, High Pressure Liquid | en_US |
dc.subject | Cross-Linking Reagents | en_US |
dc.subject | Dental Materials | en_US |
dc.subject | Humans | en_US |
dc.subject | Materials Testing | en_US |
dc.subject | Methacrylates | en_US |
dc.subject | Methylmethacrylate | en_US |
dc.subject | Methylmethacrylates | en_US |
dc.subject | Orthodontic Appliances | en_US |
dc.subject | Polymerization | en_US |
dc.subject | Polymers | en_US |
dc.subject | Polymethyl Methacrylate | en_US |
dc.subject | Temperature | en_US |
dc.subject | Terpenes | en_US |
dc.subject | Time Factors | en_US |
dc.subject | Viscosity | en_US |
dc.title | Level of residual monomer released from orthodontic acrylic materials | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 84 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 862 | |
dc.identifier.startpage | 862 | en_US |
dc.identifier.endpage | 867 | en_US |
dc.identifier.doi | 10.2319/060713-435.1 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 24601878 | en_US |
dc.identifier.scopus | 2-s2.0-84907015824 | en_US |
dc.identifier.wos | WOS:000341225800015 | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Diş Hekimliği Fakültesi Koleksiyonu PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
18
checked on Mar 29, 2025
WEB OF SCIENCETM
Citations
12
checked on Apr 2, 2025
Page view(s)
66
checked on Feb 8, 2025
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.