dc.description.abstractIn this study, the exergy and energy analyses of the Renovated Afyon Geothermal Heating System (NAFJET), which was completely renovated in the Afyon province of Turkey between the years 2011–2013, were conducted. The exergy destruction in the overall geothermal district heating system (GDHS) was quantified and illustrated using exergy flow diagrams. Both energy and exergy flow diagrams were presented for comparison purposes. The analyses revealed that the exergy destruction in the system took place particularly due to the exergy of the thermal water (geothermal fluid) re-injected, the heat exchanger losses, the losses of all pumps and pipeline loses, accounting for 15.94%, 12.44%, 5.52% and 5.52% of the total exergy input to the system. Both energy and exergy efficiencies of the overall system were investigated, and they were found to be 46.17% and 60.63%, respectively. © 2016 Elsevier B.V.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.relation.ispartofEnergy and Buildingsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDistrict heating systemen_US
dc.subjectEnergy analysisen_US
dc.subjectExergy analysisen_US
dc.subjectGeothermal energyen_US
dc.subjectDistrict heatingen_US
dc.subjectExergyen_US
dc.subjectFlowchartingen_US
dc.subjectGeothermal heatingen_US
dc.subjectHeatingen_US
dc.subjectHeating equipmenten_US
dc.subjectEnergy and exergy efficiencyen_US
dc.subjectExergy Analysisen_US
dc.subjectExergy destructionsen_US
dc.subjectExergy flow diagramen_US
dc.subjectGeothermal district heating systemen_US
dc.subjectGeothermal heating systemsen_US
dc.titleEnergy and exergy based evaluation of the renovated Afyon geothermal district heating systemen_US
dc.typeArticleen_US
dc.identifier.volume127en_US
dc.identifier.startpage794
dc.identifier.startpage794en_US
dc.identifier.endpage804en_US
dc.identifier.doi10.1016/j.enbuild.2016.06.036-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-84975842734en_US
dc.identifier.wosWOS:000381529400069en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeArticle-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Teknoloji Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

26
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

24
checked on Nov 16, 2024

Page view(s)

40
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.