Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/28650
Title: Endüstriyel tesislerde aktif harmonik filtre uygulaması ile elektrik güç kalitesinin düzenlenmesi
Other Titles: Increasing the electrical power quality in industrial facilites by active harmonic filter application
Authors: Orucu, Ethem
Advisors: Sazak, Bekir Sami
Keywords: Harmonikler
güç kalitesi
aktif harmonik filtre
ABB PQF-Size yazılımı
Harmonics
power quality
active harmonic filter
ABB PQF-Size software
Publisher: Pamukkale Üniversitesi Fen Bilimleri Enstitüsü
Abstract: Bu tez çalışmasının amacı; elektrik şebekesinde doğrusal olmayan karakteristikteki sistem bileşenlerinin meydana getirdiği enerji kalitesizliği problemi olan harmoniklerin, aktif harmonik filtreler ile sönümlenerek güç sistemi kalitesinin artırılıp, elektrik enerjisinin daha güvenli ve verimli kullanılmasını sağlamaktır. Bu bağlamda; enerji yoğun bir endüstriyel tesisin enerji güç kalitesi, enerji analizörü ile analiz edilmiştir. Sonrasında işletmedeki enerji kalite problemlerini gidermek için, bir Aktif Harmonik Filtre çözümü önerilmiştir. Web tabanlı PQF-Size yazılımı ile ABB PQFI-M45 Aktif Harmonik Filtre sisteminin benzetim çalışması yapılmıştır. Benzetim çalışmasının sonuçlarına göre; ilgili işletmenin harmoik problemlerinin ortadan kaldırıldığı sonucuna varılmıştır. Böylece, işletmenin enerji kalitesinde iyileştirme gözlenmiştir.
The aim of this thesis is to provide the usage of electricity in much more safe and efficient way by using active harmonic filters which reduce the harmful effects of harmonic distortions by usage of the system equipment with nonlineer characteristics. In this respect; in a facility which has a big energy consumption density, analysis of the energy quality has been done. After that; to eliminate the energy quality problems in that facility, an Active Harmonic Filter solution was suggested. With web-based PQF-Size software, ABB PQFI-M45 Active Harmonic Filter system was simulated. According to the simulation results, it was concluded that harmonic problems in the relevant factory were eliminated. Thus, an improvement in the energy quality of the facility was observed.
URI: https://hdl.handle.net/11499/28650
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
10329672.pdf3.43 MBAdobe PDFView/Open
Show full item record



CORE Recommender

Page view(s)

206
checked on May 27, 2024

Download(s)

268
checked on May 27, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.